Overly Door Logo
Home
About
Products
Acoustical GSA Vault Doors Bullet Resistant Blast Resistant Pressure Resistant Radiation Shielding Hybrid Custom Airtight + Gastight Hardware
Resources
Certified Installers Find a Representative Installation Instructions Quickship Program Data Sheet Ordering Product Warranty ISO Certification Specialty Applications LEED Information Freight Claims News & Events
Contact
Home
About
Product Types
Acoustical GSA Vault Doors Bullet Resistant Blast Resistant Pressure Resistant Radiation Shielding Hybrid Custom Airtight + Gastight Hardware
Browse Products
Doors Windows Hardware
Resources
Certified Installers Find a Representative Installation Instructions Quickship Program Data Sheet Ordering Product Warranty ISO Certification Specialty Applications LEED Information Freight Claims News & Events
Contact
Doors Windows Hardware
HomeProducts5492298

Product Details

Product Catalog
5492298

Single Swinging Flush Metal Door

Type: Acoustical
Perimeter Seal: Dual "H" Gasket
Bottom Seal: Super "H" Door Bottom
Door Thickness: 2.75" / 69.85mm
Min Frame Depth: 6.25" / 158.75mm
Max Leaf Size: 48" x 96"
STC Rating: 54
Max Fire Rating: 3 hr
5492298

Single Swinging Flush Metal Door

Type: Acoustical
Perimeter Seal: Dual "H" Gasket
Bottom Seal: Super "H" Door Bottom
Door Thickness: 2.75" / 69.85mm
Min Frame Depth: 6.25" / 158.75mm
Max Leaf Size: 48" x 96"
STC Rating: 54
Max Fire Rating: 3 hr
Transmission Loss in dB/Hertz - 1/3 Octave Bands
100
37
125
39
160
41
200
41
250
44
315
46
400
49
500
51
630
53
800
55
1000
55
1250
56
1600
60
2000
63
2500
64
3150
66
4000
68
5000
69

Dual "H" Perimeter Seals

This door is equipped with our patented dual Super "H" door sealing system.  It consists of a dual compression type perimeter seal.  Compression seals typically offer higher acoustical ratings.  The seal is composed of a felt/neoprene combination that forms a tight perimeter seal.  Dual compression seals are used on our highest rated acoustical doors.

UL Fire Ratings

In addition to acoustical testing, Overly has successfully tested this product to the latest UL fire test standard UL10C/UBC 7-2 (positive pressure).

Recommended Hardware:

Locks:

CylindricalANSI A156.2, Series 4000 Grade 1
3-3/4" Back-set Required
Suggested Models:
  • Best 94K
  • Schlage "ND" Series
  • Sargent 10 Series
  • Corbin/Russwin CL3300
MortiseANSI A156.13 Series 1000 Grade 1
2" maximum rosette diameter
Suggested Models:
  • Best 35H
  • Sargent 8200
  • Schlage "L" Series
  • Corbin/Russwin ML2000

Exit Devices:

Narrow MortiseANSI 156.3, Grade 1
2" maximum case width
Suggested Models:
  • Sargent 8300
  • Corbin/Russwin ED7600
  • Von Duprin 5575
RimANSI 156.3, Grade 1
Suggested Models:
  • Sargent 8800
  • Corbin/Russwin ED5200
  • Von Duprin 98/99
Surface Vertical RodANSI A156.3, Grade 1
Suggested Models:
  • Sargent 8700
  • Von Duprin 9927
  • Corbin/Russwin ED6400

Flush-Bolts:

6-3/4" x 1"ANSI 156.16
Suggested Models:
  • Ives 458
  • Rockwood 555

Hinges:

Full Mortise Cam-Lift
Suggested Models:
  • Overly MCL-1000

Thresholds:

Saddle
Must have smooth top, no ridges or grooves
Suggested Models:
  • Reese S105
  • Pemko 154
  • NGP 412
  • Zero 164

Closers:

Surface MountedANSI 156.4 Grade 1
Rigid arms are not recommended.
Suggested Models:
  • Corbin/Russwin DC2000, DC3000, DC4000
  • Dorma 8600, 8900
  • LCN 4010, 4020, 4041 Super Smoothie
  • Norton 7500, 8500
  • Sargent 250, 251, 350, 351, 1230, 1231, 1250, 1251

Support Documents:

Catalogs

Acoustical Products Catalog

CAT-001
Rev: 11
.pdf
Cut Sheets

5492298 Cut Sheet

ENGD-061
Rev: 3
.pdf

Available Sound Control Wall Anchorage Systems For 2-3/4" Thick Metal Acoustical Door With Dual Compression Perimeter Seals

ENGD-119
Rev: 2
.pdf

Typical Sound Control Sill Systems For 2-3/4" & 3" Thick Metal Acoustical Door With Super "H" Door Bottom

ENGD-097
Rev: 1
.pdf
Data Sheets

Acoustical Metal Door Data Sheet

SALD-001
Rev: 4
.pdf
Edge Section

2-3/4" Thick Metal Acoustical Door Isolated Edge Construction

DET-004
Rev: 0
.pdf

2-3/4" Thick Metal Acoustical Door Isolated Edge Construction

DET-004
Rev: 0
.dwg
Elevation

Flush Single Door Elevation

DET-041
Rev: 0
.pdf

Flush Single Door Elevation

DET-041
Rev: 0
.dwg
Handing Charts

Handing Chart for Single Swing Door

DET-046
Rev: 0
.pdf

Handing Chart for Single Swing Door

DET-046
Rev: 0
.dwg
Horizontal Section

2-3/4" Thick Single Metal Acoustical Door with Dual "H" Perimeter Seals, Cam-Lift Hinges, & Lock

DET-007
Rev: 0
.dwg

2-3/4" Thick Single Metal Acoustical Door with Dual "H" Perimeter Seals, Cam-Lift Hinges, & Lock

DET-007
Rev: 0
.pdf
Installation Instructions

Installation Instructions for 2-3/4" & 3" Acoustical Panel Door Units - Dual "H" Seals and Super "H" Door Bottoms

SPIIINS0005
Rev: 5
.pdf
Sill Section

2-3/4" And 3" Thick Doors with Super "H" Door Bottom

DET-113
Rev: 0
.dwg
Specifications

Sound Retardant Swinging Metal Door Assemblies Specification

ENGD-021
Rev: 3
.doc

Sound Retardant Swinging Metal Door Assemblies Specification

ENGD-021
Rev: 3
.pdf
Technical Bulletins

Metal Sound Retardant Door Hardware Information Bulletin

ENGD-018
Rev: 11
.pdf

Required Jamb Openings Widths to Meet ADA Clearance Requirements for 1-3/4", 1-7/8", 2-1/4", 2-1/2", 2-3/4", and 3" Thick Doors

TBD04
Rev: 2
.pdf

SCIF Lock Compatibility Overview

SCIF
Rev: 0
.pdf

Sound Retardant Doors and Windows Monograph

ENGD-038
Rev: 3
.pdf
Templates

MCL-1000 Cam-Lift Hinge Template

ENGD-005
Rev: 3
.pdf
Test Reports

Accelerated Physical Endurance Test for Acoustical Door Units with MCL-500 Cam-Lift Hinges

PHY-30091
Rev: 1
.pdf

Acoustical Test Report - STC5492298

TL92-298
Rev: 0
.pdf

Test for compliance to ADA Requirements for Door Openings with MCL-500 Cam-Lift Hinges

PHY-40306
Rev: 0
.pdf
Vertical Section

2-3/4" Thick Metal Acoustical Door with Dual "H" Perimeter Seals & Super "H" Door Bottom

DET-023
Rev: 0
.dwg

2-3/4" Thick Metal Acoustical Door with Dual "H" Perimeter Seals & Super "H" Door Bottom

DET-023
Rev: 0
.pdf
Wall Section

Dual Compression Seals - Bolt-In Installation In Existing Poured Concerete Wall or Existing Masonry Wall

DET-116
Rev: 0
.pdf

Dual Compression Seals - Bolt-In Installation In Existing Poured Concerete Wall or Existing Masonry Wall

DET-116
Rev: 0
.dwg

Dual Compression Seals - Bolt-In Installation In Existing Stud Wall

DET-118
Rev: 0
.dwg

Dual Compression Seals - Bolt-In Installation In Existing Stud Wall

DET-118
Rev: 0
.pdf

Dual Compression Seals - Built In Installation In New Masonry Wall

DET-120
Rev: 0
.pdf

Dual Compression Seals - Built In Installation In New Masonry Wall

DET-120
Rev: 0
.dwg

Dual Compression Seals - Built In Installation In New Stud Wall

DET-122
Rev: 0
.dwg

Dual Compression Seals - Built In Installation In New Stud Wall

DET-122
Rev: 0
.pdf

Dual Compression Seals - Optional Split Type Frame For Bolt In Installation In Existing Stud Wall

DET-124
Rev: 0
.pdf

Dual Compression Seals - Optional Split Type Frame For Bolt In Installation In Existing Stud Wall

DET-124
Rev: 0
.dwg

Get Started

Are you an architect, contractor, or distributor? Find your local Overly Representative to get started.

In the United States:

Contact your Overly Door Representative:

Submit State Required

International:

For international sales and distributors:

Intl. Distributors
Intl. Sales Representatives
351 Harvey Avenue, Suite B
Greensburg, PA 15601
1 (800) 979-7300
Contact Us Now

ISO 9001:2015

As of June 25, 2021 Overly Door Company has been recertified as meeting the new ISO 9001:2015 standard.

More About ISO Certification
© 2025 Overly Door Company. All Rights Reserved.
Privacy Policy|Freight Claims|General Conditions of Sale|Product Warranty|Industry Links